Product Range |
|
|
PRESSURE INSTRUMENTS |
|
|
|
TEMPERATURE INSTRUMENTS |
|
|
|
LEVEL INSTRUMENTS |
|
|
|
|
FLOW INSTRUMENTS |
|
|
|
HUMIDITY INSTRUMENTS |
|
|
|
CLEANROOM INSTRUMENT |
|
|
|
|
HVAC / BMS SENSORS |
|
|
|
AIR QUALITY SENSOR |
|
|
|
WATER QUALITY SENSOR |
|
|
|
PH1001-Transmitter Without Display |
|
PH1011-Transmitter With Display |
|
TDS691-Transmitter Without Display |
|
EC691-Conductivity Transmitter Without Display |
|
EC692-Conductivity Transmitter With Display |
|
ORP-1001-ORP Transmitter Without Display |
|
DOT-6400-Submersible Galvanic Dissolved Oxygen Sensors |
|
CL5-Free Chlorine Sensors |
|
Watertest K-100-TH-Total/Ca-Hardness Controller |
|
TBD-99-Online Turbidity Meter |
|
WH:Total Hardness Automatic Analyzer |
|
CD4: Chlorine Dioxide Sensors |
|
SA-300: Silica Analyser |
|
SA-300H: Silica(SiO2) Analyzer |
|
PHSEN: Laboratory pH Electrodes |
PH1001-Transmitter Without Display |
|
PH1011-Transmitter With Display |
|
TDS691-Transmitter Without Display |
|
EC691-Conductivity Transmitter Without Display |
|
EC692-Conductivity Transmitter With Display |
|
ORP-1001-ORP Transmitter Without Display |
|
DOT-6400-Submersible Galvanic Dissolved Oxygen Sensors |
|
CL5-Free Chlorine Sensors |
|
Watertest K-100-TH-Total/Ca-Hardness Controller |
|
TBD-99-Online Turbidity Meter |
|
WH:Total Hardness Automatic Analyzer |
|
CD4: Chlorine Dioxide Sensors |
|
SA-300: Silica Analyser |
|
SA-300H: Silica(SiO2) Analyzer |
|
|
VAV BOXES |
|
|
|
BTU METER |
|
|
|
VALVES |
|
|
|
INDICATORS & CONTROLLERS |
|
|
|
DATALOGGER |
|
|
|
PORTABLE INSTRUMENTS |
|
|
|
ACCESSORIES |
|
|
|
ONLINE CATALOGUE |
|
|
|
CATALOGUE REQUEST |
|
|
|
|
SA-300H: Silica(SiO2) Analyzer |
|
|
Special Features |
|
|
Convenient maintenance |
|
- |
Easy tube replacement & disassembly - No defect due to simplified
structure - Data storage function (USB) |
|
7” Color LCD Monitor |
|
Display of data trend |
|
Alarm function for lack of reagents or sample |
|
Automatic calibration by standard solution |
|
Multichannel operation (1~6ch) |
|
Applications |
|
- |
Monitoring and control of the boiler water, feed water. |
|
- |
Power Plants, Semiconductor Industry. |
|
|
|
|
|
Specifications |
|
|
Model |
SA - 300 |
SA - 300H |
|
Resolution |
Colorimetric
(Molybdenum blue) |
Colorimetric
(Molybdenum yellow) |
|
Measuring Range |
0~50 to 0~500
ppb 0~3,000 ppb |
0~50 ppm |
|
Display (Resolution) |
0.1 ppb (0.5 ppb) |
0.1 ppm (0.5 ppm) |
|
Accuracy |
± 1.0 ppb or ± 2% of reading |
± 2% of reading |
|
Response Time |
12 min App. |
12 min App. |
|
Sample Pressure |
1~ 5 bar |
|
Sample Temperature |
5 ~ 45°C |
|
Sample Flow |
200~500 ml /min |
|
Sample Connections |
Inlet 6mm / Outlet 10mm |
|
Reagent Consumption |
80 days (A, C, STD/2L, B/1L) |
|
Data Output |
4 ~ 20 mA, RS485 Modbus |
|
Dimensions |
400W X 500H X 200D (Flush type), |
|
|
530W X 1700H X 300D (Self -standing type) |
|
Power |
100~240 VAC (50/60 Hz) |
|
|
|
|
|
|
|